Diaphragm Gas Meters: What Minimum-Flow Inspection Reveals in Service

Published on 11.24

Diaphragm Gas Meters: What Minimum-Flow Inspection Reveals in Service

Abstract

Cen及其同事从一家天然气公司正在使用的J2.5膜式燃气表中随机抽取了2,000台。他们检测了最小流量、最大流量的20%和最大流量下的示值误差,同时检查了外观和密封性。在两个精度等级和所有三个使用年限组中,最小流量下的示值合格率均最低。在B级燃气表中,使用三年、六年和九年时的小流量合格率分别为79.23%、86.43%和29.43%。该研究说明了按流量分别统计的结果如何能够揭示那些在单一综合检验合格率中被掩盖的差异。

Background and research question

A meter inspection can combine several decisions about the same unit. Appearance and tightness checks are distinct from tests of the volume indication. The indication itself can behave differently at minimum flow and at the upper end of the rated range. A single pass rate is useful for a fleet summary, but it does not show which part of the inspection produced the result. This distinction matters when specifying what a supplier or inspection laboratory needs to report.
Cen and colleagues sampled in-service J2.5 diaphragm meters to study the accuracy of the indication after different periods of service. This article focuses on the original sample and the first four source tables. The question is which test point distinguished the reported outcomes most clearly, and whether an overall pass rate alone can describe the differences between groups.

Sample selection and test method

The paper reports a random sample of 2,000 meters from one natural gas company. It grouped them by class and service duration. There were 444 Class A units and 1,556 Class B units. The group sizes were unequal. For example, at three years the sample contained 73 Class A and 361 Class B meters. At nine years it contained 229 Class A and 333 Class B meters. Table 1 retains each count so that readers can see the denominator behind the separate rates.
The study employed a bell prover with accuracy class 0.5. It used air at a test temperature of 20 ± 2 °C, ambient pressure of 86–106 kPa and relative humidity of 45–75%. Meters were left in those test conditions for four hours before inspection. The researchers tested each meter twice at the lower flow limit qₘᵢₙ, at 0.2 qₘₐₓ and at qₘₐₓ. They also checked appearance and tightness. The source discusses a repeatability criterion and an exception at the lowest flow when describing its screening method. The published results use the study's own screening and historical evaluation criteria.
Class
3 years (meters)
6 years (meters)
9 years (meters)
Total (meters)
A
73
142
229
444
B
361
862
333
1556
Total
434
1004
562
2000

Results by flow point and service group

Tables 2 and 3 give the reported pass rates for Class A and Class B. The minimum flow had the lowest indication pass rate within each class and service-age category. At nine years, for example, Class B meters passed the indication check at rates of 29.43% at qₘᵢₙ, 70.87% at 0.2 qₘₐₓ and 83.79% at qₘₐₓ. The gap between the first and last figures is 54.36 percentage points, calculated from the displayed table. Quoting only the maximum-flow outcome would hide this difference.
The Class A and Class B patterns show why the age categories also need to remain visible. Minimum-flow pass rates for Class B were 79.23%, 86.43% and 29.43% at three, six and nine years. The Class A cohorts had rates of 6.85%, 66.20% and 85.16%. The cohorts show different trends. The study compared groups of meters at different service ages. It did not follow one set of meters repeatedly through the three age points. Consequently, the category differences do not directly measure individual changes over time.
The discussion of severe indication deviations provides another way to read the results. Table 4 reports the proportion of Class B meters with an absolute relative indication error above 50%. At nine years, the proportion was 20.12% at qₘᵢₙ, 6.91% at 0.2 qₘₐₓ and 5.71% at qₘₐₓ. These are percentages within the relevant group and point. The three entries are not additive because a meter could contribute a result at more than one flow. The Class A and B tables report full passes for appearance and tightness among the tested groups, alongside very different outcomes for indication. Each check addresses a separate property.
Inspection item
3 years (%)
6 years (%)
9 years (%)
qₘᵢₙ
6.85
66.20
85.16
0.2 qₘₐₓ
84.94
97.19
95.64
qₘₐₓ
87.68
97.19
96.51
Tightness
100.00
100.00
100.00
Appearance
100.00
100.00
100.00
Overall
6.85
66.20
85.16
Inspection item
3 years (%)
6 years (%)
9 years (%)
qₘᵢₙ
79.23
86.43
29.43
0.2 qₘₐₓ
95.85
93.39
70.87
qₘₐₓ
97.79
96.40
83.79
Tightness
100.00
100.00
100.00
Appearance
100.00
100.00
100.00
Overall
79.23
86.43
29.43
Flow point
3 years (%)
6 years (%)
9 years (%)
qₘᵢₙ
1.67
3.37
20.12
0.2 qₘₐₓ
0.84
1.28
6.91
qₘₐₓ
0.84
1.16
5.71

Conclusion and limits of the comparison

The study supports recording and reviewing the minimum-flow result independently in an inspection dataset. Across the reported groups, it was the most discriminating of the three indication test points. The combination of Table 1 and the class-specific tables lets a reader see which sample and test produced each percentage. Repeating the comparison at more than one flow is especially useful when the meter spends much of its operating time near the low end of its range.
These findings apply to the sampled company, historic test criteria, meter type and tested service groups. They do not establish a universal replacement interval or a pass rate for another meter design. A follow-up could report manufacturer and cohort composition, retain the tested denominators at each point and follow the same meters over time. For an equipment or inspection inquiry, specify the expected lowest operating flow, ask for separate indication results at the agreed flow points and request the sample date and group sizes.

Notes

Rates in Tables 2–4 are reproduced as percentages. The 54.36-point difference is an editorial calculation from Table 3. The flow symbols refer to the minimum and maximum flow rates in the original test. This article uses Sections 2 and 3. The separate distribution modeling and the author biography are outside the adopted range.

References and Image Sources

[1] Cen, K., Wang, H., Yuan, X., and Li, W. (2009). Inspection and Analysis of Measurement Indication Error for Diaphragm Gas Meter in Use. Gas & Heat, 29(11), B11–B14. Author publication index · Independent journal citation, reference 30
Tables 1–4. Cen et al. [1]. Original values transcribed from the published tables with English labels. No in-range source figures.
Cover. Sergey Sergeev / Pexels. Stock photograph cropped for a text layout. Photo · Pexels License