Smart Gas Monitoring Devices: Basement Signal Quality and Meter Report Success
Abstract
A strong signal at a test location does not establish whether an NB-IoT gas meter will consistently deliver its reports. Li and colleagues compared four antenna-and-meter combinations in a basement, a laboratory and an outdoor setting. They measured received signal power, signal-to-noise ratio and report success during three daily windows. The basement was the weakest setting overall, and the effect of antenna choice differed between meter bodies. Average reporting rates across the study exceeded 99%, while individual environment and time-window results were lower. This article explains how to read the three measurements together when evaluating an installation.
Background and research question
An NB-IoT gas meter can record consumption locally and transmit a reading to a remote system. A communications review needs to establish how often those transmissions arrive under the conditions the installation will face. A single radio-strength reading gives limited evidence about this outcome. The receiving device may see a strong reference signal relative to another meter and still experience noise or other conditions that affect reporting. Likewise, an aggregate success rate may mask a particular building or time window.
Li and colleagues asked whether two antenna types and two meter-body designs performed similarly across three environments. Their field data allow two separate comparisons. First, does the same meter-and-antenna combination change from one environment to another? Second, do combinations with similar received power produce similarly useful signals and reporting results at the same location? Keeping these comparisons separate helps a buyer ask for relevant evidence.
Samples and measurements
The study paired an on-board steel-sheet antenna or an externally connected PCB antenna with each of two meter bodies. Base meter 1 used an aluminum housing and base meter 2 used a steel housing. The two bodies also differed in shape and construction, so the test did not isolate housing material as the sole variable. All configurations used the same model of communications module. Thirty meters were selected for each configuration. The researchers first recorded total radiated power and total isotropic sensitivity in a chamber. The chamber results describe the radio system under controlled conditions and establish a comparison point for the subsequent site measurements.
The site measurements covered a second-basement parking area, an indoor laboratory and an unobstructed outdoor area. The tests ran for ten consecutive days, with hourly sessions at 01:00–02:00, 11:00–12:00 and 21:00–22:00. During each session the meters attempted a report every five minutes. The paper analyzes reference signal received power, or RSRP, in dBm, and signal-to-noise ratio, or SNR, in dB. It calculates report success as the number of successful reports divided by the number attempted. Table 3 keeps the radio means and the three time-window results together.
Set | Base meter | Antenna |
1 | Aluminum base meter 1 | On-board steel-sheet antenna |
2 | Steel base meter 2 | On-board steel-sheet antenna |
3 | Aluminum base meter 1 | External PCB antenna |
4 | Steel base meter 2 | External PCB antenna |
Results and discussion
The basement produced the weakest received signal levels for all four configurations in Table 3. For example, Combination 3 averaged −107.9 dBm in the basement and −68.4 dBm outdoors. The difference is an observation from two locations, rather than a fixed building-loss figure. Figure 1 also shows differences among individual units within each configuration. A mean alone would conceal those differences.
A second comparison illustrates why received power needs a companion measure. In the basement the mean RSRP for Combinations 1 and 4 was −113.7 and −113.1 dBm, respectively. The respective mean SNR values were 1.4 and −3.5 dB. The power readings were close, while the noise-relative readings differed by 4.9 dB, calculated from the table. Outdoors the same pair had a different SNR ordering, with 14.9 dB for Combination 1 and 17.3 dB for Combination 4. One location therefore cannot establish which configuration will lead at another site. Figures 1–6 preserve the study's unit-level comparisons in all three environments.
The authors report overall mean reporting rates above 99% for the combinations in the studied settings. Some individual windows were lower than other windows. Combination 2, for example, recorded 99.0%, 99.3% and 99.1% in the basement for the three listed windows. Some entries tie across windows or differ from the broad pattern discussed by the authors. Read the numbers for the intended location and time rather than treating the general early-morning pattern as universal. The paper discusses network congestion and interference as possible contributors, but its field observations do not isolate traffic from propagation, local equipment or other influences.
Comparisons across environments are most interpretable when the report window is held fixed. Conversely, comparisons across windows should keep the meter set and site fixed. These two comparisons use different denominators in practice: one describes performance across installation conditions, while the other describes performance over the selected reporting periods.
Set | TRP (dBm) | TIS (dBm) |
1 | 19.42 | −111.84 |
2 | 18.56 | −111.33 |
3 | 19.31 | −112.17 |
4 | 19.12 | −112.61 |
Set | Environment | Mean RSRP (dBm) | Mean SNR (dB) | 01:00–02:00 (%) | 11:00–12:00 (%) | 21:00–22:00 (%) |
1 | Basement | −113.7 | 1.4 | 99.2 | 99.5 | 99.4 |
1 | Indoor | −84.2 | 6.4 | 99.5 | 99.8 | 99.6 |
1 | Outdoor | −68.7 | 14.9 | 99.7 | 100.0 | 99.9 |
2 | Basement | −120.3 | −4.4 | 99.0 | 99.3 | 99.1 |
2 | Indoor | −88.4 | 7.4 | 99.5 | 99.6 | 99.8 |
2 | Outdoor | −76.9 | 7.8 | 99.7 | 99.9 | 99.8 |
3 | Basement | −107.9 | 6.4 | 99.6 | 99.7 | 99.7 |
3 | Indoor | −82.7 | 14.9 | 99.8 | 99.9 | 99.8 |
3 | Outdoor | −68.4 | 20.7 | 99.9 | 100.0 | 100.0 |
4 | Basement | −113.1 | −3.5 | 99.4 | 99.7 | 99.5 |
4 | Indoor | −85.2 | 10.3 | 99.7 | 99.9 | 99.8 |
4 | Outdoor | −71.0 | 17.3 | 99.9 | 100.0 | 99.8 |
Figure 1. Received reference-signal power by meter number in the basement for four body-and-antenna sets. Original Figure 1 from Li et al. [1]. English labels substituted.
Figure 2. Signal-to-noise ratio by meter number in the basement for four body-and-antenna sets. Original Figure 2 from Li et al. [1]. English labels substituted.
Figure 3. Received reference-signal power by meter number in the indoor laboratory for four body-and-antenna sets. Original Figure 3 from Li et al. [1]. English labels substituted.
Figure 4. Signal-to-noise ratio by meter number in the indoor laboratory for four body-and-antenna sets. Original Figure 4 from Li et al. [1]. English labels substituted.
Figure 5. Received reference-signal power by meter number at the unobstructed outdoor site for four body-and-antenna sets. Original Figure 5 from Li et al. [1]. English labels substituted.
Figure 6. Signal-to-noise ratio by meter number at the unobstructed outdoor site for four body-and-antenna sets. Original Figure 6 from Li et al. [1]. English labels substituted.
Conclusion and outlook
The study supports collecting both radio and reporting evidence in the environment where the meters will operate. The basement observations show that similar reference-signal power can accompany different signal-to-noise ratios. The time-window data show why an overall reporting percentage should be read with its underlying settings. The four tested configurations, one module model and three selected sites limit the comparison. Different buildings, installation enclosures and network operators could produce different results.
For a deployment inquiry, specify the installation location and the intended reporting cadence. Ask how the test defines a successful report, how many attempts were made, and whether the results include a window with unusually high reporting demand. A later site verification can then compare the proposed installation with the evidence actually reported.
Notes
RSRP is reference signal received power. SNR is signal-to-noise ratio. TRP is total radiated power and TIS is total isotropic sensitivity. The paper gives the chamber expression Iₜᵣₚ = 10 lg P (1), where Iₜᵣₚ is total radiated power level in dBm and P is the numerical value of total radiated power in mW. The symbol lg denotes the base-ten logarithm. The column differences discussed above are editorial calculations from the published table. No current regulatory approval or site-wide service level is inferred.
References and Image Sources
[1] Li, J., Cui, W., Tang, L., Song, S., Cheng, H., and Liu, X. (2025). Wireless Performance and Environmental Adaptability of NB-IoT Smart Gas Meters. Gas & Heat, 45(8), 52–57.
Original paper record ·
DOI as printed in the paperFigures 1–6 and Tables 1–3. Li et al. [1]. Figures reproduced from the original paper with English legend and axis labels. Tables transcribed into English with original numbers and units.
Cover. Mikhail Nilov / Pexels. Stock photograph cropped for a text layout.
Photo ·
Pexels License